{"product_id":"pressure-relief-valves-for-cryogenic-liquids","title":"Pressure-Relief Valves for Cryogenic Liquids","description":"\u003ch2 style=\"text-align: center;\"\u003ePressure-Relief Valves for Cryogenic Liquids\u003c\/h2\u003e\n\u003ctable style=\"undefined;table-layout: fixed; width: 574px;\" class=\"tg\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 209px;\"\u003e \u003ccol style=\"width: 365px;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-uw1k\"\u003eValve Function\u003c\/th\u003e\n\u003cth class=\"tg-uw1k\"\u003ePressure Relief\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eFor Use With\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eLiquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eActivation\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003ePressure Driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-gyvu\"\u003eInlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003ePipe Size\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003e1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003ePipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003ePipe Connection Type\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eThreaded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eNPT Male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eLocation\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eBottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eMaximum Pressure\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003e600 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-gyvu\"\u003eRelief Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eThread Size\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003e3\/4\"-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003ePipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003ePipe Connection Type\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eThreaded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eUNEF Female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eLocation\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eTop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eSet Pressure Accuracy\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eSet Pressure Configuration\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eNonadjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003e-320° to 165° F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eShape\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eStraight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eOverall Height\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003e2 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-gyvu\"\u003eMaterial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eBody\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eValve Type\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eRelief\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eFlow Coefficient (Cv)\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eNot Rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eSpecifications Met\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eCGA G-4.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eRoHS\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eRoHS 3 (2015\/863\/EU) compliant with exemption 6(c) - Lead in copper alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eREACH\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eNot Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eDFARS\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eSpecialty Metals COTS-Exempt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eUSMCA Qualifying\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eSchedule B\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003e848140.0000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ml3l\"\u003eECCN\u003c\/td\u003e\n\u003ctd class=\"tg-ml3l\"\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCleaned and bagged to meet CGA G-\u003cspan class=\"Wrd\"\u003e4.\u003c\/span\u003e1 for oxygen service and other high purity\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003eapplications,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ethese valves are built to withstand the extreme cold of liquid carbon\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003edioxide,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eliquid\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003enitrogen,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eand liquid\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003eoxygen.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThey begin opening at the set pressure and fully open at about\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003e10%\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eover the set\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003epressure.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eValves begin closing as pressure drops and fully close when the system pressure is restored below the set\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003epressure.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSet pressure is not\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003eadjustable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"shell-contentcontainer\" id=\"ShellLayout_Content_Cntnr\"\u003e\n\u003cdiv id=\"ShellLayout_MainContent_Cntnr\"\u003e\n\u003cdiv class=\"ShellLayout_MainContent_Inner_SecondaryContent_Collapsed\" id=\"ShellLayout_MainContent_Inner\"\u003e\u003cmain id=\"MainContent\"\u003e\n\u003cdiv id=\"Itm_49315K71\" class=\"ItmPrsnttnWebPart\"\u003e\n\u003cdiv class=\"HideOnItmPrsnttnPrint\"\u003e\n\u003cdiv class=\"ItmPrsnttnStruc2\"\u003e\n\u003cdiv class=\"am\"\u003e\n\u003cdiv class=\"cntnr--product-info dq\"\u003e\n\u003cdiv class=\"CpyCntnr\"\u003e\n\u003cp class=\"copy\"\u003eValves are not intended for direct contact with cryogenic\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003eliquids.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eRisers\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003e(sold\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003eseparately)\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eare required to convert cryogenic liquids into gases before they contact the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003evalve.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003e\u003cspan class=\"ae\"\u003e3\/8\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNPT valve requires a\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003e\u003cspan class=\"ae\"\u003e1\/2\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003eNPT ×\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003e\u003cspan class=\"ae\"\u003e3\/8\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eNPT bushing when using a\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"Wrd\"\u003eriser.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"clearDiv\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/main\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfooter id=\"Shell_BottomNavWebPart_Cntnr\"\u003e\u003c\/footer\u003e","brand":"BVV","offers":[{"title":"250 psi","offer_id":51602242601280,"sku":"49315K71-250","price":120.0,"currency_code":"USD","in_stock":true},{"title":"350 psi","offer_id":51602242634048,"sku":"49315K71-350","price":150.0,"currency_code":"USD","in_stock":true},{"title":"400 psi","offer_id":51602242666816,"sku":"49315K71-400","price":120.0,"currency_code":"USD","in_stock":true},{"title":"450 PSI","offer_id":51602242699584,"sku":"49315K71-450","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0696\/7335\/3536\/files\/49315K71_a28069cb-48a6-46d0-b2c8-0d05627059fb.jpg?v=1772988736","url":"https:\/\/growtime.shop\/products\/pressure-relief-valves-for-cryogenic-liquids","provider":"Grow Time Garden Supply","version":"1.0","type":"link"}